Battery energy storage containers beside solar panels and wind turbines

C&I Storage Solutions

Cabinet-type storage behind the meter – lower bills, uninterrupted production

Outdoor-rated battery cabinets connected to the main LV board of the facility, with no major change to the existing installation. Power (kW) and energy (kWh) are sized independently, and parallel cabinets scale to multi-MWh.

Open C&I battery cabinet with liquid-cooled LFP modules

C&I Storage Solutions

Cabinet-type, outdoor-rated storage for factories, logistics, hospitality, EV charging and critical facilities – connected behind the meter to the main LV board with no major change to the existing installation.

  • 372.7 – 418 kWh per battery cabinet; 0.5C and 1C variants
  • Parallel cabinets scale to multi-MWh
  • Liquid-cooled LFP in an IP55 outdoor enclosure
  • Cabinet footprint ~1.7 m²; PCS, access and separation distances are additional
  • Separate PCS: power (kW) and energy (kWh) sized independently
  • PV coupling and grid-forming options for backup and island operation
  • Protection, metering and LV connection adapted to each site
  • Commissioning typically within days once site works are complete

What it does for your site

The same cabinet does all of these in turn; the NEOS EMS decides which has priority at any hour. Where the energy is drawn from does not change – when it is drawn does.

Lowers the bill

Charges in low-price hours and discharges in peak hours; the energy line of the bill drops directly.

Keeps production running

On grid loss the load continues without interruption; no downtime, scrap or data loss.

Carries solar into the evening

Midday rooftop surplus is used in the evening peak instead of being sold cheaply or lost.

Prevents demand overrun

Peaks above the contracted capacity are served by the battery; no penalties and no transformer upgrade when a new machine, chiller or charger is added.

Cuts generator hours

Generators run fewer hours at better load; less fuel, longer maintenance intervals, lower emissions.

Ready for grid services

Infrastructure in place for demand-side participation and balancing revenues as markets open.

Key data

Three cabinet models on one LFP cell platform – the choice depends on whether the site needs long discharge, high power or the highest capacity per footprint.

ParameterCabinet · EnergyCabinet · PowerCabinet · High Capacity
Rated energy372.7 kWh372.7 kWh418 kWh
C-rate · typical duration0.5C · 2 h1C · 1 h0.5C · 2 h
Best suited forLong discharge; bill-driven sitesHigh power; peak shaving & backupHighest capacity per footprint
DC voltage range900 – 1,500 Vdc1,165 – 1,500 Vdc1,165 – 1,500 Vdc
CellLFP 280 AhLFP 280 AhLFP 314 Ah
Enclosure · coolingOutdoor cabinet · IP55 · liquidOutdoor cabinet · IP55 · liquidOutdoor cabinet · IP55 · liquid
Dimensions (W × D × H) · weight1,300 × 1,300 × 2,375 mm · ~4 t1,300 × 1,300 × 2,375 mm · ~4 t1,300 × 1,300 × 2,375 mm · ~4 t
CommunicationCAN · RS485CAN · RS485CAN · RS485
CertificationCE · UN 38.3 · IEC 62619 · UL 1973 · UL 9540A

Operating range: charge 0 ~ 45 °C, discharge −20 ~ 50 °C. Values per manufacturer technical documentation; final configuration subject to project specification.

Typical sites

C&I

Manufacturing plants

Peak-hour bill and demand overrun; the line must not stop.

C&I

Cold storage

Temperature must hold during an outage; no product loss.

C&I

Hotels and shopping malls

The evening consumption peak coincides with the evening price peak.

C&I

EV charging hubs

Several vehicles charging at once exceed the transformer; the battery supports the connection.

C&I

Data centres and hospitals

Uninterrupted supply and a soft transfer to the generator.

C&I

Organised industrial zones

Shared storage and demand management for several subscribers.

What is added to the site

The battery is commissioned as a cabinet connected to the facility’s main LV board. Protection, metering and the LV connection are adapted to each site; the PCS is a separate unit so that power and energy are sized independently.

~1.7 m²

battery cabinet footprint; PCS, access and separation distances are added in the layout

Days

to commission once civil works, cabling and the grid connection are ready

Multi-MWh

by connecting identical cabinets in parallel

Indoor C&I battery cabinet line-up
Indoor C&I cabinet line-up at an industrial facility
Outdoor C&I battery cabinet next to an EV charger
Outdoor C&I cabinet supporting on-site EV charging
Rack-based battery system in a dedicated battery room
Rack-based, air-cooled system in a dedicated battery room
NEOS Enerji